- Up to 87% seasonal efficiency.
- Wet leg design to ensure maximum efficiency and reduce heat loss.
- Aquastat mounted in coil plate to speed domestic water response times.
- Large variety of venting options.
- Couplings are used instead of nipples to lower the risk of thread damage during shipping and handling.
- Recessed supply coupling to reduce air in system
- Front-and rear-mounted fittings provide flexible installation options.
- Prepunched casings are packaged separately to prevent shipping damage and for ease of handling during installation.
- Choice of Riello or Beckett high efficiency burners.
- Compact size uses less of your valuable floor space.
- Standard nut and bolt design on coil mounting eliminates studs.
- Insulated casings for heat retention.
- Available with cold start capability
20 year limited warranty
Certified To: CSA B140.7.1, CSA B212 (EEV) and UL726
Specifications
OB1000
- 20"d x 20"w x 33"h
- Shipping Weight 370 lbs
- Supply & Return 1-¼"
- Water Capacity: 15 US Gal
- 6" O.D. Breech Pipe
OB2000
- 23-¼"d x 23-¼"w x 38-½"h
- Shipping Weight 515 lbs
- Supply & Return 1-¼"
- Water Capacity: 20 US Gal
- 8" O.D. Breech Pipe
- Certified for installation with L-Vent
- Select Models are ENERGY STAR COMPLIANT
- Optional Balanced Flue available on selected models
- Optional power venting available on selected models
- Optional CRN Approval available on selected models
- OB1000 - CRN7818.8970432YT
- OB2000 - CRN7819.8970432YT
- Domestic Hot Water Coil Available
- OB1000 can be installed on combustible floor
Riello Burners Burner Insertion - F5, BF3 & BF5=3-1/8" ; F3 & F10=3-1/2" | |||||||||
Model | Series | Input US GPH |
Nozzle Size | Pump PSIG | Riello Model | TBLTR | Air (INITIAL) | Output BTU | Efficiency |
R105 | 1000 | 0.85 | 0.75 60A | 130 | F3 | 0.5 | 7.8 | 102,000 | 85.9 |
R120 | 1000 | 1.00 | 0.85 60W | 140 | F5 | 1.0 | 3.2 | 120,000 | 85.9 |
R150 | 1000 | 1.25 | 1.00 60W | 155 | F5 | 2.0 | 5.6 | 147,000 | 85.1 |
R180 | 1000 | 1.50 | 1.25 60W | 145 | F5 | 3.0 | 8.0 | 176,000 | 85.1 |
OB85BF3 | 1000 | 0.75 | .65 80W | 130 | BF3 | 5.5 | 1.5 | 91,400 | 87.5 |
OB100BF3 | 1000 | 0.89 | .75 80W | 140 | BF3 | 5.8 | 3.0 | 108,900 | 87.8 |
OB120BF5 | 1000 | 1.00 | .85 60W | 145 | BF5 | 4.5 | 2.0 | 121,500 | 87.7 |
OB150BF5 | 1000 | 1.28 | 1.10 60W | 135 | BF5 | 6.0 | 3.0 | 153,600 | 86.1 |
R215 | 2000 | 1.75 | 1.50 60A | 135 | F10 | 0.0 | 4.0 | 213,000 | 85.1 |
R250 | 2000 | 2.00 | 1.75 60A | 130 | F10 | 1.0 | 5.0 | 243,000 | 85.1 |
R275 | 2000 | 2.25 | 2.00 60A | 125 | F10 | 2.0 | 6.0 | 271,000 | 86.4 |
R330 | 2000 | 2.80 | 2.25 60A | 155 | F10 | 4.5 | 8.0 | 328,000 | 84.2 |
Beckett Burners Burner Insertion: 2-3/4" | |||||||||
Model | Series | Input US GPH | Nozzle Size | Pump PSIG | Beckett Model AFII | PIN# | Air (INITIAL) | Output BTU | Efficiency |
B90 | 1000 | 0.75 | 0.65 70A | 140 | 85-HLX50HD | 4 | 7.0 | 90,000 | 86.1 |
B107 | 1000 | 0.89 | 0.75 70A | 140 | 85-HLX50HD | 5 | 7.5 | 107,000 | 86.2 |
B120 | 1000 | 1.00 | 0.85 60B | 140 | 150-HLX50HC | 0 | 4.0 | 120,000 | 86.1 |
B150 | 1000 | 1.18 | 1.00 60B | 140 | 150-HLX50HC | 5 | 4.5 | 140,000 | 84.9 |
B180 | 1000 | 1.50 | 1.25 70B | 140 | 150-HLX50HC | 8 | 5.0 | 174,000 | 83.2 |