CC500 Combination Oil/Wood Hot Water Boiler
- The "DUTCH OVEN" concept of completely surrounding both fireboxes with cooling water prevents damage from over heating and eliminates the need for fire brick.
- Unique compact size uses less of your valuable floor space.
- Couplings used instead of nipples to prevent shipping and handling damage.
- Completely separate oil and wood firebox chambers.
- Wood on top for ease of loading.
- 23.25" long firebox.
- primary control kit pre-wired.
- Compact unit; easy to install; less piping; neater job.
- CC500 does not sacrifice oil efficiency to burn wood.
- No fires tubes means the unit is easier to clean.
- Two rear-mounted coils for domestic hot water.
6 year limited warranty
Certified to: CSA B140.7.1, CAN/CSA B366.1, UL391 and UL 726
Specifications
- Shipping Weight : 890 lbs
- 29-¾"l x 24-¼"w x 47"h
- Supply & Return 1-¼"
- Water Capacity: 40 US gallons
- 2 - 7" I.D. Smoke Pipe.
- Oil 17-½" LC Height
- Wood 39-½" LC Height
- 12" x 14" Cast Iron Wood Fire Door
Control Kit
- 2 Transformers
- 1 Flame Retention Burner
- 1 Damper Motor/Chain
- 1 Pressure Relief Valve
- 1 Blocked Flue Sensor
- 1 1/2" Drain Valve
- 1 Triple Aquastat/ Well
- 1 Tridicator
- 1 Triple Aquastat Relay/Well
- 2 Circulator Pumps
- 1 Single Aquastat/ Well
- 1 N.O. Zone Valve
Riello Burners Burner Insertion - F5 4-1/8 | ||||||||
Model | Input US GPH |
Nozzle Size | Pump PSIG | Riello Model | TBLTR | Air (INITIAL) |
Output BTU |
Efficiency Oil |
CC500R | 0.90 | .75 X 80°B | 145 | F5 | 1.50 | 3.5 | 107,000 | 85.3 |
CC500R | 1.02 | .85 X 80°B | 145 | F5 | 3.25 | 3.75 | 120,700 | 84.9 |
Beckett Burners Burner Insertion: 4" | ||||||||
Model | Input US GPH |
Nozzle Size | Pump PSIG | Beckett Model | Air (INITIAL) |
Output BTU | Efficiency Oil | |
CC500B | 0.89 | .75 X 80°B | 140 | AFG | 10 1 | 106,600 | 84.9 | |
CC500B | 1.00 | .85 X 80°B | 140 | AFG | 10 2 | 118,700 | 85.1 |