BACK TO ALL PRODUCTS

CC500: Indoor Wood & Oil Combination Boiler

Made in Canada

The CC500 provides you the best of both worlds for your home heating boiler. This unit is for indoor wood & oil burning and will automatically switch to oil in the event that the wood heat reaches the lower temperature you set. This allows you to heat your home without feat that your home will be cold upon your return while also giving you the ability to lower your heating bill when using wood.

The Benjamin Heating Difference

  • The "DUTCH OVEN" concept of completely surrounding both fireboxes with cooling water prevents damage from over heating and eliminates the need for fire brick.
  • Unique compact size uses less of your valuable floor space.
  • Couplings used instead of nipples to prevent shipping and handling damage.
  • Completely separate oil and wood firebox chambers.
  • Wood on top for ease of loading.
  • 23.25" long firebox.
  • primary control kit pre-wired.
  • Compact unit; easy to install; less piping; neater job.
  • CC500 does not sacrifice oil efficiency to burn wood.
  • No fires tubes means the unit is easier to clean.
  • Two rear-mounted coils for domestic hot water.
  • Certified to: CSA B140.7.1, CAN/CSA B366.1, UL391 and UL 726
  • 6 Year Limited Warranty

CC500: Indoor Wood & Oil Combination Boiler

Specifications

Certified to: CSA B140.7.1, CAN/CSA B366.1, UL391 and UL 726

CC500 Specifications

Shipping Weight

890 lbs

Overall Dimensions

29-3/4” L x 24-1/4” W x 47” H

Smoke Pipe

2 - 7” I.D. Smoke Pipe

Firebox Size

20"dia. x 23.25"

Fire Door Size

12” x 14” Cast Iron Wood Fire Door

Wood Length

23" Long Log

Water Capacity

40 US Gallons

Supply & Return

1-1/4”

Domestic Coil

2 Rear Mounted Coils

Typical Add-on Installation Kit Included with Boiler

2 Transformers

1 Flame Retention Burner

1 Damper Motor/Chain

1 Pressure Relief Valve

1 Blocked Flue Sensor

1 1/2" Drain Valve

1 Triple Aquastat/ Well

1 Tridicator

1 Triple Aquastat Relay/Well

2 Circulator Pumps

1 Single Aquastat/ Well

1 N.O. Zone Valve

Riello Burners Burner Insertion - F5 4-1/8

Model
Input US GPH
Nozzle Size
Pump PSIG
Riello Model
TBLTR
Air (INITIAL)
Output BTU
Efficiency Oil
CC500R
0.90
.75 X 80°B
145
F5
1.50
3.5
107,000
85.3
CC500R
1.02
.85 X 80°B
145
F5
3.25
3.75
120,700
84.9

Beckett Burners Burner Insertion: 4"

Model
Input US GPH
Nozzle Size
Pump PSIG
Beckett Model
Air (INITIAL)
Output BTU
Efficiency Oil
CC500B
0.89
.75 X 80°B
140
AFG
10 1
106,600
84.9
CC500B
1.00
.85 X 80°B
140
AFG
10 2
118,700
85.1